TheLawyer.sh
Tilbage

EUR-Lex - 31967R0162 - EN

31967R0162

Den Europæiske UnionForordning1967

European Union

§ ARTICLE 1

ARTICLE 1

1 . WHEN THE REFUND ON WHEAT OR SPELT FLOUR AND MESLIN FLOUR IS BEING FIXED , THE QUANTITIES OF WHEAT NECESSARY FOR THE MANUFACTURE OF 1000 KG OF THESE PRODUCTS SHALL BE , ACCORDING TO THEIR ASH CONTENT REFERRED TO DRY MATTER , AS FOLLOWS :

ASH CONTENT PER 100 G OF FLOUR ( EXPRESSED IN MG ) NUMBER OF KG OF COMMON WHEAT PER 1000 KG OF FLOUR

0 TO 520 1510

521 TO 600 1430

601 TO 900 1330

901 TO 1100 1230

1101 TO 1650 1140

1651 TO 1900 1020

2 . WHEN THE REFUND ON RYE FLOUR IS BEING FIXED , THE QUANTITIES OF RYE NECESSARY FOR THE MANUFACTURE OF 1000 KG OF THIS PRODUCT SHALL BE , ACCORDING TO THEIR ASH CONTENT REFERRED TO DRY MATTER , AS FOLLOWS :

ASH CONTENT PER 100 G OF FLOUR ( EXPRESSED IN MG ) NUMBER OF KG OF PER 1000 KG OF FLOUR

0 TO 700 1540

701 TO 850 1410

851 TO 1150 1260

1151 TO 1400 1170

1401 TO 1600 1120

1601 TO 1800 1070

1801 TO 2000 1020

3 . WHEN THE REFUND ON WHEAT GROATS AND MEAL ( COMMON WHEAT AND DURUM WHEAT ) IS BEING FIXED , THE QUANTITY OF COMMON WHEAT OR DURUM WHEAT NECESSARY FOR THE MANUFACTURE OF 1000 KG OF THESE PRODUCTS SHALL BE 1580 KG .

4 . THE ASH CONTENT OF FLOUR REFERRED TO IN PARAGRAPHS 1 AND 2 SHALL BE DETERMINED ACCORDING TO THE METHOD OF ANALYSIS SPECIFIED IN THE ANNEX TO THIS REGULATION .

§ ARTICLE 2

ARTICLE 2

THIS REGULATION SHALL ENTER INTO FORCE ON 1 JULY 1967 .

THIS REGULATION SHALL BE BINDING IN ITS ENTIRETY AND DIRECTLY APPLICABLE IN ALL MEMBER STATES .

DONE AT BRUSSELS , 23 JUNE 1967 .

FOR THE COMMISSION

THE PRESIDENT

WALTER HALLSTEIN

ANNEX

METHOD OF DETERMINING THE ASH CONTENT OF FLOUR

APPARATUS

1 . LABORATORY SCALES SENSITIVE TO 0.01 MG .

BOX OF CORRESPONDING WEIGHTS .

2 . ELECTRIC MUFFLE KILN , WITH ADEQUATE DRAUGHT AND A TEMPERATURE GAUGE AND REGULATOR .

3 . ROUND , FLAT-BOTTOMED INCINERATION DISHES ( ABOUT 5 CM IN DIAMETER , MAXIMUM HEIGHT 2 CM ) , PREFERABLY OF GOLD AND PLATINUM ALLOY OR OF QUARTZ OR PORCELAIN .

4 . DESICCATOR ( WITH AN INTERNAL DIAMETER OF ABOUT 18 CM ) FITTED WITH A NECK AND A PERFORATED PLATE , IN PORCELAIN OR ALUMINIUM .

DEHYDRATION AGENT : CALCIUM CHLORIDE , PHOSPHORUS PENTOXIDE OR SILICA GEL COLOURED BLUE .

METHOD

1 . THE WEIGHT OF THE TEST SAMPLE SHOULD BE BETWEEN 5 AND 6 G . WHEN IT IS FLOUR OF WHICH THE ASH CONTENT REFERRED TO DRY MATTER IS LIKELY TO BE OVER 1 % , THE WEIGHT OF THE TEST SAMPLE SHOULD BE BETWEEN 2 AND 3 G . THE WEIGHT OF THE TEST SAMPLE MAY BE ROUNDED TO THE NEAREST 10 MG ; ALL OTHER QUANTITIES ARE WEIGHED TO THE NEAREST 0.1 MG .

2 . IMMEDIATELY BEFORE USE THE DISHES MUST BE HEATED IN THE MUFFLE KILN AT INCINERATION TEMPERATURE TO CONSTANT WEIGHT ; A PERIOD OF FIFTEEN MINUTES IS USUALLY SUFFICIENT .

THE DISHES ARE THEN COOLED IN THE DESICCATOR TO LABORATORY TEMPERATURE UNDER THE CONDITIONS INDICATED IN PARAGRAPH 7 .

3 . PLACE THE TEST SAMPLE IN THE DISH AND SPREAD IT OUT IN AN EVEN LAYER , WITHOUT HEAPING . IMMEDIATELY BEFORE INCINERATION DAMP THE TEST SAMPLE WITH 1 TO 2 ML OF ETHYL ALCOHOL .

4 . PLACE THE DISHES IN THE MOUTH OF THE KILN , THE DOOR OF WHICH REMAINS OPEN . WHEN THE SUBSTANCE HAS CEASED TO FLAME , PUSH THE DISHES INTO THE KILN . WHEN THE KILN DOOR HAS BEEN CLOSED , AN ADEQUATE DRAUGHT MUST BE MAINTAINED , BUT NOT SO STRONG AS TO BLOW THE SUBSTANCE OUT OF THE DISHES .

5 . INCINERATION MUST RESULT IN THE TOTAL COMBUSTION OF THE FLOUR , INCLUDING ANY SOOTY PARTICLES AMONG THE ASHES . IF SHALL BE CONSIDERED AS COMPLETED WHEN THE RESIDUE IS ALMOST WHITE AFTER COOLING .

6 . THE INCINERATION TEMPERATURE MUST REACH 900 C .

7 . WHEN INCINERATION IS COMPLETED , REMOVE THE DISHES FROM THE KILN AND PLACE THEM ON A SHEET OF ETERNIT FOR ABOUT ONE MINUTE TO COOL , THEN PUT THEM IN THE DESICCATOR ( NOT MORE THAN FOUR DISHES AT A TIME ) . THE CLOSED DESICCATOR IS PLACED NEAR THE ANALYSIS SCALES . WEIGH THE DISHES WHEN THEY ARE COMPLETELY COLD ( ABOUT ONE HOUR ) .

RESULTS

1 . MARGIN OF ERROR : IF THE ASH CONTENT DOES NOT EXCEED 1 % , THE RESULTS OF A DOUBLE TEST SHOULD NOT DIFFER BY MORE THAN 0.02 UNITS OF ASH CONTENT ; IF THE ASH CONTENT EXCEEDS 1 % , THE DIFFERENCE SHOULD NOT EXCEED 2 % OF THE ASH CONTENT . IF THE DIFFERENCE EXCEEDS THESE LIMITS THE TEST MUST BE REPEATED .

2 . THE ASH CONTENT SHALL BE STATED PER 100 PARTS OF DRY MATTER AND ROUNDED TO 0.01 .

Metadata

Type
Forordning
År
1967
Ikrafttrædelsesdato
1. januar 1970