Commission Regulation (EU) 2019/521 of 27 March 2019 amending, for the purposes of its adaptation to technical and scientific progress Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixturesText with EEA relevance.
European Union
Commission Regulation (EU) 2019/521 of 27 March 2019 amending, for the purposes of its adaptation to technical and scientific progress Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures (Text with EEA relevance) THE EUROPEAN COMMISSION, Having regard to the Treaty on the Functioning of the European Union, Having regard to Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 OJ L 353, 31.12.2008, p. 1. , and in particular Article 53(1) thereof, Whereas: (1) Regulation (EC) No 1272/2008 harmonises the provisions and criteria for the classification, labelling and packaging of substances and mixtures and certain specific articles within the Union. (2) Regulation (EC) No 1272/2008 takes into account the Globally Harmonised System of Classification and Labelling of Chemicals (GHS) of the United Nations (UN). (3) The classification criteria and labelling rules of the GHS are periodically reviewed at the UN level. The sixth and seventh revised editions of the GHS result from changes adopted in 2014 and 2016 respectively by the United Nations Committee of Experts on the Transport of Dangerous Goods and on the Globally Harmonised System of Classification and Labelling of Chemicals. (4) The sixth and seventh revised editions of the GHS trigger the need to amend some technical provisions and criteria on classification, labelling and packaging in Regulation (EC) No 1272/2008. In particular, these further developments of the GHS introduce a new hazard class for desensitised explosives and a new hazard category, pyrophoric gases, within the hazard class flammable gases. Other changes include adaptations to: the criteria for substances and mixtures which in contact with water emit flammable gases, the generic cut-off values; the general provisions to classify aerosol forms of mixtures; and the detail of the definitions and classification criteria as appropriate for the hazard classes explosives, flammable gases, flammable liquids, flammable solids, acute toxicity, skin corrosion/irritation, serious eye damage/eye irritation, respiratory and skin sensitisation, germ cell mutagenicity, carcinogenicity, reproductive toxicity, specific target organ toxicity and aspiration hazard. In addition, amendments are introduced to some hazard and precautionary statements. It is therefore necessary to adapt some technical provisions and criteria in Annexes I, II, III, IV, V and VI to Regulation (EC) No 1272/2008 to take account of the sixth and seventh revised editions of the GHS. (5) Regulation (EC) No 1272/2008 should therefore be amended accordingly. (6) To ensure that suppliers of substances and mixtures have time to adapt to the new classification, labelling and packaging provisions, the application of this Regulation should be deferred.
(7) In line with the transitional provisions of Regulation (EC) No 1272/2008 which allow the application of the new provisions at an earlier stage on a voluntary basis, suppliers should have the possibility of applying the new classification, labelling and packaging provisions on a voluntary basis before the date of application of this Regulation. (8) The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 133 of Regulation (EC) No 1907/2006 of the European Parliament and of the Council Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC (OJ L 396, 30.12.2006, p. 1). , HAS ADOPTED THIS REGULATION:
Article 1
Regulation (EC) No 1272/2008 is amended as follows: (1) Annex I is amended in accordance with Annex I to this Regulation; (2) Annex II is amended in accordance with Annex II to this Regulation; (3) Annex III is amended in accordance with Annex III to this Regulation; (4) Annex IV is amended in accordance with Annex IV to this Regulation; (5) Annex V is amended in accordance with Annex V to this Regulation; (6) Annex VI is amended in accordance with Annex VI to this Regulation
Article 2
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union. It shall apply from 17 October 2020. By way of derogation from the second paragraph, substances and mixtures may, before 17 October 2020, be classified, labelled and packaged in accordance with this Regulation. This Regulation shall be binding in its entirety and directly applicable in all Member States. Done at Brussels, 27 March 2019. For the Commission The President Jean-Claude Juncker
Annex
ANNEX I Annex I to Regulation (EC) No 1272/2008 is amended as follows:
- Part 1 is amended as follows: (a) In section 1.1.2.2.2, Table 1.1 is replaced by the following: Table 1.1 Generic cut-off values Or < 1 % where relevant, see 3.2.3.3.1. Or < 1 % where relevant, see 3.3.3.3.1. Or < 1 % where relevant, see 3.8.3.4.6. Or < 0,1 % where relevant, see 4.1.3.1. Hazard classGeneric cut-off values to be taken into accountAcute Toxicity: Category 1-3 0,1 % Category 4 1 %Skin corrosion/Irritation1 %Serious damage to eyes/eye irritation1 %Specific target organ toxicity, single exposure, Category 31 %Aspiration toxicity1 %Hazardous to Aquatic Environment Acute Category 1 0,1 % Chronic Category 1 0,1 % Chronic Category 2-4 1 % (b) Section 1.1.3.7 is replaced by the following: 1.1.3.7. Aerosols In the case of the classification of mixtures covered by sections 3.1, 3.2, 3.3, 3.4, 3.8 and 3.9, an aerosol form of a mixture shall be classified in the same hazard category as the tested non-aerosolised form of the mixture, provided that the added propellant does not affect the hazardous properties of the mixture upon spraying.
(c) Section 1.3.2.1 is replaced by the following: 1.3.2.1. If propane, butane and liquefied petroleum gas or a mixture containing these substances classified in accordance with the criteria of this Annex, is placed on the market in closed refillable cylinders or in non-refillable cartridges within the scope of EN 417 as fuel gases which are only released for combustion (current edition of EN 417, relating to Non-refillable metallic gas cartridges for liquefied petroleum gases, with or without a valve, for use with portable appliances; construction, inspection, testing and marking), these cylinders or cartridges need be labelled only with the appropriate pictogram and the hazard and precautionary statements concerning flammability. 2. Part 2 is amended as follows: (a) In section 2.1.1.1, point (c) is replaced by the following: (c) substances, mixtures and articles not mentioned in points (a) and (b) above, which are manufactured with the view to producing a practical explosive or pyrotechnic effect. (b) In section 2.1.2.2, point (f) is replaced by the following: (f) Division 1.6 Extremely insensitive articles which do not have a mass explosion hazard: articles which predominantly contain extremely insensitive substances or mixtures; and which demonstrate a negligible probability of accidental initiation or propagation. (c) In section 2.1.4.1, the third paragraph is replaced by the following: Some explosive substances and mixtures are wetted with water or alcohols, diluted with other substances or dissolved or suspended in water or other liquid substances to suppress or reduce their explosives properties. They may be a candidate for classification as desensitised explosives (see Section 2.17). (d) In section 2.1.4.1, figure 2.1.3 is replaced by the following: Figure 2.1.3 Procedure for assignment to a division in the class of explosives (Class 1 for transport) DIVISION 1.1 DIVISION 1.2 DIVISION 1.3 DIVISION 1.5 DIVISION 1.6 NOT AN EXPLOSIVE Is the major hazard that from dangerous projections? Is the result a mass explosion? Is the substance/mixture a candidate for Divison 1.5? Would the hazard hinder firefighting in the immediate vicinity? Is the major hazard radiant heat and/or violent burning but with no dangerous blast or projection hazard? Is it an extremely insensitive article? Is the article a candidate for Division 1.6? Is it a very insensitive explosive substance/mixture with a mass explosion hazard? Is the substance/mixture or article manufactured with the view of producing a practical explosive or pyrotechnic effect? Are there hazardous effects outside the package? Is the product article excluded by definition? (se 2.1.1.1 (b)) Package the substance/mixture Does special provision 347 apply? (1) DIVISION 1.4 Compatibility groups other than S DIVISION 1.4 Compatibility group S TEST SERIES 5 TEST SERIES 6 ARTICLE OR SUBSTANCE/MIXTURES PROVISIONALLY ACCEPTED IN THIS CLASS (from figure 2.1.2) TEST SERIES 7 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes Yes No No No No No No No No No No No (1) See Chapter 3.3 of the UN RTDG, Model Regulations for details. (e) Section 2.1.4.3 is amended as follows: (i) the introductory wording is replaced by the following: 2.1.4.3. The acceptance procedure for the hazard class explosives need not be applied if: (ii) point (c) is replaced by the following: (c) For an organic substance, or a homogenous mixture of organic substances, containing a chemical group (or groups) associated with explosive properties: the exothermic decomposition energy is less than 500 J/g, or the onset of exothermic decomposition is 500 °C or above as indicated in Table 2.1.3. (iii) Table 2.1.3 is added to 2.1.4.3 (c): Table 2.1.3 Decision to apply the acceptance procedure for the hazard class Explosives for an organic substance or a homogenous mixture of organic substances Decomposition energy (J/g) Decomposition onset temperature (°C) Apply acceptance procedure? (Yes/No) < 500< 500No< 500≥ 500No≥ 500< 500Yes≥ 500≥ 500No The exothermic decomposition energy may be determined using a suitable calorimetric technique (see section 20.3.3.3 of the UN RTDG, Manual of Tests and Criteria). (f) In section 2.2 the title is replaced by the following: 2.2. Flammable gases (g) Section 2.2.1 is replaced by the following: 2.2.1. Definitions 2.2.1.1. Flammable gas means a gas or gas mixture having a flammable range with air at 20 °C and a standard pressure of 101,3 kPa. 2.2.1.2. A pyrophoric gas means a flammable gas that is liable to ignite spontaneously in air at a temperature of 54 °C or below. 2.2.1.3. A chemically unstable gas means a flammable gas that is able to react explosively even in the absence of air or oxygen. (h) Sections 2.2.2.1 and 2.2.2.2 are replaced by the following: 2.2.2.1. A flammable gas is classified in Category 1A, 1B or 2 in accordance with Table 2.2.1. Flammable gases that are pyrophoric and/or chemically unstable are always classified in Category 1A. Table 2.2.1 Criteria for categorisation of flammable gases CategoryCriteria1AFlammable gas Gases, which at 20 °C and a standard pressure of 101,3 kPa are: (a) ignitable when in a mixture of 13 % or less by volume in air; or (b) have a flammable range with air of at least 12 percentage points regardless of the lower flammability limit unless data show they meet the criteria for Category 1B Pyrophoric gasFlammable gases that ignite spontaneously in air at a temperature of 54 °C or belowChemically unstable gasAFlammable gases which are chemically unstable at 20 °C and a standard pressure of 101,3 kPaBFlammable gases which are chemically unstable at a temperature greater than 20 °C and/or a pressure greater than 101,3 kPa1BFlammable gas Gases which meet the flammability criteria for Category 1A, but which are not pyrophoric, nor chemically unstable, and which have at least either: (a) a lower flammability limit of more than 6 % by volume in air; or (b) a fundamental burning velocity of less than 10 cm/s; 2Flammable gasGases, other than those of Category 1A or 1B, which, at 20 °C and a standard pressure of 101,3 kPa, have a flammable range while mixed in air.
NOTE 1: Aerosols shall not be classified as flammable gases. See Section 2.3. NOTE 2: In the absence of data allowing classification into Category 1B, a flammable gas that meets the criteria for Category 1A is classified by default in Category 1A. NOTE 3: Spontaneous ignition for pyrophoric gases is not always immediate, and there may be a delay. NOTE 4: In the absence of data on its pyrophoricity, a flammable gas mixture shall be classified as a pyrophoric gas if it contains more than 1 % (by volume) of pyrophoric component(s). (i) In section 2.2.3, Table 2.2.3 is replaced by the following: Table 2.2.2 Label elements for flammable gases Category 1AGases categorised as 1A meeting pyrophoric or unstable gas A/B criteriaCategory 1BCategory 2Pyrophoric gasChemically unstable gasCategory ACategory BGHS PictogramNo pictogramSignal WordDangerDangerDangerDangerDangerWarningHazard StatementH220: Extremely flammable gas H220: Extremely flammable gas. H232: May ignite spontaneously if exposed to air H220: Extremely flammable gas. H230: May react explosively even in the absence of air H220: Extremely flammable gas. H231: May react explosively even in the absence of air at elevated pressure and/or temperature H221: Flammable gasH221: Flammable gasPrecautionary Statement PreventionP210 P210 P222 P280 P202 P210 P202 P210 P210P210Precautionary Statement Response P377 P381 P377 P381 P377 P381 P377 P381 P377 P381 P377 P381 Precautionary Statement StorageP403P403P403P403P403P403Precautionary Statement Disposal The classification procedure is set out in the following decision logic (see Figure 2.2.1). (j) In section 2.2.3, the following paragraph is added after Table 2.2.2: If a flammable gas or gas mixture is classified as pyrophoric and/or chemically unstable, then all relevant classification(s) shall be communicated on the safety data sheet as specified in Annex II of Regulation (EC) No 1907/2006, and the relevant hazard communication elements included on the label. (k) In section 2.2.3, Figure 2.2.1 is replaced with the following: Figure 2.2.1 Flammable gases Category 1A Chemically unstable gas A Category 1A Pyrophoric gas Category 1A Pyrophoric gas and chemically unstable gas B Danger Danger Danger Danger Category 1A Pyrophoric gas and chemically unstable gas A Is it chemically unstable at 20 °C and a standard pressure of 101,3 kPa? Is it chemically unstable at a temperature greater than 20 °C and/or a pressure greater than 101,3 kPa? Is it chemically unstable at 20 °C and a standard pressure of 101,3 kPa? Does it ignite spontaneously in air at 54 °C or below? (1) Not classified as a flammable gas Does it have a flammable range with air at 20 °C and a standard pressure of 101,3 kPa? Yes No No No Yes Yes No No Yes Yes The substance/mixure is a gas (1) In the absence of data on its pyrophoricity, a flammable gas mixture shall be classified as a pyrophoric gas if it contains more than 1 % (by volume) of pyrophoric component(s). Category 2 No pictogram Warning Does it have a lower flammability limit > 6 % by volume in air, and/or does it have a fundamental burning velocity < 10 cm/s?
At 20 °C and a standard pressure of 101,3 kPa, does it: (a) ignite when a mixture of 13 % or less by volume in air?; or (b) have a flammable range with air of at least 12 percentage poins regardless of the lower flammability limit? Is it chemically unstable at a temperature greater than 20 °C and/or a pressure greater than 101,3 kPa? No or unknown Yes Yes Yes No No Category 1B Category 1A Danger Danger Danger Category 1A Chemically unstable gas B (l) In section 2.2.3, Figure 2.2.2 is deleted. (m) Section 2.2.4 is amended as follows: Section 2.2.4.1 is replaced by the following: 2.2.4.1. Flammability shall be determined by tests or, for mixtures where there are sufficient data available, by calculation in accordance with the methods adopted by ISO (see ISO 10156 as amended, Gases and gas mixtures — Determination of fire potential and oxidising ability for the selection of cylinder valve outlets and, if using fundamental burning velocity for Category 1B, see ISO 817 as amended Refrigerants-Designation and safety classification, Annex C:- Method of test for burning velocity measurement of flammable gases). Instead of the test apparatus according to ISO 10156 as amended, the test apparatus for the tube method according to clause 4.2 of EN 1839 as amended (Determination of explosion limits of gases and vapours) may be used. The following sections 2.2.4.2 and 2.2.4.3 are inserted: 2.2.4.2. Pyrophoricity shall be determined at 54 °C in accordance with either IEC 60079-20-1 ed1.0 (2010-01) Explosive atmospheres – Part 20-1: Material characteristics for gas and vapour classification – Test methods and data or DIN 51794 Determining the ignition temperature of petroleum products. 2.2.4.3. The classification procedure for pyrophoric gases need not be applied when experience in production or handling shows that the substance does not ignite spontaneously on coming into contact with air at a temperature of 54 °C or below. Flammable gas mixtures, which have not been tested for pyrophoricity and contain more than one percent pyrophoric components, shall be classified as a pyrophoric gas. Expert judgement on the properties and physical hazards of pyrophoric gases and their mixtures shall be used in assessing the need for classification of flammable gas mixtures containing one percent or less pyrophoric components. In this case, testing need only be considered if expert judgement indicates a need for additional data to support the classification process. (n) Section 2.2.4.2 is renumbered as follows: 2.2.4.4. (o) The text before paragraphs (a) to (d) in section 2.6.4.2 is replaced by the following: 2.6.4.2. In the case of mixtures Up to now, the calculation method is validated for mixtures containing up to six volatile components. These components may be flammable liquids like hydrocarbons, ethers, alcohols, esters (except acrylates), and water. It is however not yet validated for mixtures containing halogenated, sulphurous, and/or phosphoric compounds as well as reactive acrylates.
containing known flammable liquids in defined concentrations, although they may contain non-volatile components e.g. polymers, additives, the flash point need not be determined experimentally if the calculated flash point of the mixture, using the method given in 2.6.4.3 below, is at least 5 °C If the calculated flash point is less than 5 °C greater than the relevant classification criterion, the calculation method may not be used and the flash point shall be determined experimentally. greater than the relevant classification criterion and provided that: (p) Section 2.7.2.2 is replaced by the following: 2.7.2.2. Powders of metals or metal alloys shall be classified as flammable solids when they can be ignited and the reaction spreads over the whole length of the sample (100 mm) in 10 min or less. (q) In section 2.12.2.1, Table 2.12.1 is replaced by the following: Table 2.12.1 Criteria for substances and mixtures, which in contact with water, emit flammable gases CategoryCriteria1Any substance or mixture which reacts vigorously with water at ambient temperatures and demonstrates generally a tendency for the gas produced to ignite spontaneously, or which reacts readily with water at ambient temperatures such that the rate of evolution of flammable gas is equal to or greater than 10 litres per kilogram of substance over any one minute.2Any substance or mixture which reacts readily with water at ambient temperatures such that the maximum rate of evolution of flammable gas is equal to or greater than 20 litres per kilogram of substance per hour, and which does not meet the criteria for Category 1.3Any substance or mixture which reacts slowly with water at ambient temperatures such that the maximum rate of evolution of flammable gas is greater than 1 litre per kilogram of substance per hour, and which does not meet the criteria for Categories 1 and 2. Note: The test shall be performed on the substance or mixture in its physical form as presented. If, for example, for the purposes of supply or transport, the same chemical is to be presented in a physical form different from that which was tested and which is considered likely to materially alter its performance in a classification test, the substance must also be tested in the new form. (r) The following section 2.17 is added: 2.17. Desensitised explosives 2.17.1. Definitions and general considerations 2.17.1.1. Desensitised explosives are solid or liquid explosive substances or mixtures which are phlegmatised to suppress their explosive properties in such a manner that they do not mass explode and do not burn too rapidly and therefore may be exempted from the hazard class Explosives (see also paragraph 3 in section 2.1.4.1) Unstable explosives as defined in Section 2.1 can also be stabilised by desensitisation and consequently may be classified as desensitised explosives, provided all criteria of Section 2.17 are met. In this case the desensitised explosive shall be tested according to test series 3 (Part I of the UN RTDG, Manual of Tests and Criteria) because information about its sensitiveness to mechanical stimuli is likely to be important for determining conditions for safe handling and use. The results shall be communicated in the safety data sheet.
2.17.1.2. The hazard class of desensitised explosives comprises: (a) Solid desensitised explosives: explosive substances or mixtures, which are wetted with water or alcohols or are diluted with other substances, to form a homogeneous solid mixture to suppress their explosive properties. NOTE: This includes desensitisation achieved by formation of hydrates of the substances. (b) Liquid desensitised explosives: explosive substances or mixtures, which are dissolved or suspended in water or other liquid substances, to form a homogeneous liquid mixture to suppress their explosive properties. 2.17.2. Classification criteria 2.17.2.1. Any explosive while in a desensitised state shall be considered in this class unless, in that state: (a) It is intended to produce a practical explosive or pyrotechnic effect; (b) It has a mass explosion hazard according to test series 6 (a) or 6 (b) or the corrected burning rate according to the burning rate test described in part V, subsection 51.4 of the UN RTDG, Manual of Tests and Criteria is greater than 1200 kg/min; or (c) The exothermic decomposition energy is less than 300 J/g. NOTE 1: Substances or mixtures, which meet the criterion (a) or (b) in their desensitised state shall be classified as explosives (see Section 2.1). Substances or mixtures which meet the criterion (c) may fall within the scope of other physical hazard classes. NOTE 2: The exothermic decomposition energy may be estimated using a suitable calorimetric technique (see section 20, sub-section 20.3.3.3 in Part II of the UN RTDG, Manual of Tests and Criteria). 2.17.2.2. Desensitised explosives shall be classified and packaged for supply and use in one of the four categories of this class depending on the corrected burning rate (Ac) using the test burning rate test (external fire) described in Part V, sub-section 51.4 of the UN RTDG, Manual of Tests and Criteria, according to Table 2.17.1: Table 2.17.1. Criteria for desensitised explosives CategoryCriteria1Desensitised explosives with a corrected burning rate (AC) equal to or greater than 300 kg/min but not more than 1200 kg/min2Desensitised explosives with a corrected burning rate (AC) equal to or greater than 140 kg/min but less than 300 kg/min 3Desensitised explosives with a corrected burning rate (AC) equal to or greater than 60 kg/min but less than 140 kg/min4Desensitised explosives with a corrected burning rate (AC) less than 60 kg/min Note 1: Desensitised explosives shall be prepared so that they remain homogeneous and do not separate during normal storage and handling, particularly if desensitised by wetting. The manufacturer/supplier shall give information in the safety data sheet about the shelf-life and instructions on verifying desensitisation. Under certain conditions the content of desensitising agent (e.g. phlegmatiser, wetting agent or treatment) may decrease during supply and use, and thus, the hazard potential of the desensitised explosive may increase. In addition, the safety data sheet shall include advice on avoiding increased fire, blast or projection hazards when the substance or mixture is not sufficiently desensitised.
Note 2: Explosive properties of desensitised explosives shall be determined by test series 2 of the UN RTDG, Manual of Tests and Criteria, and shall be communicated in the safety data sheet. Note 3: For the purposes of storage, supply and use, desensitised explosives do not fall additionally within the scope of Sections 2.1 (explosives), 2.6 (flammable liquids) and 2.7 (flammable solids). 2.17.3. Hazard communication Label elements shall be used for liquid or solid substances or mixtures meeting the criteria for classification in this hazard class in accordance with Table 2.17.2. Table 2.17.2. Label elements for desensitised explosives Category 1Category 2Category 3Category 4GHS PictogramSignal wordDangerDangerWarningWarningHazard statementH206 Fire, blast or projection hazard; increased risk of explosion if desensitising agent is reducedH207 Fire or projection hazard; increased risk of explosion if desensitising agent is reducedH207 Fire or projection hazard; increased risk of explosion if desensitising agent is reducedH208: Fire hazard; increased risk of explosion if desensitising agent is reducedPrecautionary statement Prevention P210 P212 P230 P233 P280 P210 P212 P230 P233 P280 P210 P212 P230 P233 P280 P210 P212 P230 P233 P280 Precautionary Statement Response P370 + P380+ P375 P370 + P380+ P375 P370 + P380+ P375 P371 + P380 + P375 Precautionary Statement StorageP401P401P401P401Precautionary Statement DisposalP501P501P501P501 2.17.4. Additional classification considerations Figure 2.17.1. Desensitised explosives No Explosive Division 1.1 Explosive Division 1.1 Hazard class “Explosives” (see criteria in Section 2.1) Yes No Not classified as a desensitised explosive May fall within the scope of other physical hazard classes Yes Yes Danger Danger Yes Is the result a mass explosion? Test 6(a), 6(b) Is the exothermic decomposition energy less than 300 J/g? Does it contain an explosive substance or mixture which is phlegmatised to suppress the explosive properties? The substance/mixture is a solid or liquid? No Yes No AC > 1 200 kg/min? Is the result a mass explosion? Burning rate test (Part V, sub-section 51.4) AC ≥ 60 kg/min but < 140 kg/min Category 4 Category 3 Category 2 AC < 60 kg/min Warning Yes No AC ≥ 140 kg/min but < 300 kg/min No Warning Danger Danger Category 1 Yes Yes Yes AC ≥ 300 kg/min but < 1 200 kg/min No No 2.17.4.1. The classification procedure for desensitised explosives does not apply if: (a) The substances or mixtures contain no explosives according to the criteria in Section 2.1; or (b) The exothermic decomposition energy is less than 300 J/g. 2.17.4.2. The exothermic decomposition energy shall be determined using the explosive already desensitised (i.e.: the homogenous solid or liquids mixture formed by the explosive and the substance(s) used to suppress its explosive properties). The exothermic decomposition energy may be estimated using a suitable calorimetric technique (see Section 20, sub-section 20.3.3.3 in Part II of the UN RTDG, Manual of Tests and Criteria).
- Part 3 is amended as follows: (a) Section 3.1.1.1 is replaced by the following: 3.1.1.1. Acute toxicity means serious adverse health effects (i.e., lethality) occurring after a single or short-term oral, dermal or inhalation exposure to a substance or mixture. (b) In section 3.1.2.1, the introductory paragraph is replaced by the following: 3.1.2.1. Substances can be allocated to one of four hazard categories based on acute toxicity by the oral, dermal or inhalation route according to the numeric cut-off criteria as shown in the table below. Acute toxicity values are expressed as (approximate) LD50 (oral, dermal) or LC50 (inhalation) values or as acute toxicity estimates (ATE). While some in vivo methods determine LD50/LC50 values directly, other newer in vivo methods (e.g. using fewer animals) consider other indicators of acute toxicity, such as significant clinical signs of toxicity, which are used as a reference to assign the hazard category. Explanatory notes are shown following Table 3.1.1. (c) In section 3.1.2.1 the title of Table 3.1.1 is replaced by the following: Table 3.1.1 Acute toxicity estimate (ATE) values and criteria for acute toxicity hazard categories. (d) Section 3.2.1.1 is replaced by the following: 3.2.1.1. Skin corrosion means the production of irreversible damage to the skin; namely, visible necrosis through the epidermis and into the dermis occurring after exposure to a substance or mixture. Skin irritation means the production of reversible damage to the skin occurring after exposure to a substance or mixture. (e) Section 3.3.1.1 is replaced by the following: 3.3.1.1. Serious eye damage means the production of tissue damage in the eye, or serious physical decay of vision, which is not fully reversible, occurring after exposure of the eye to a substance or mixture. Eye irritation means the production of changes in the eye, which are fully reversible, occurring after the exposure of the eye to a substance or mixture. (f) Section 3.4.1.1 is replaced by the following: 3.4.1.1. Respiratory sensitisation means hypersensitivity of the airways occurring after inhalation of a substance or a mixture. (g) Section 3.4.1.2 is replaced by the following: 3.4.1.2. Skin sensitisation means an allergic response occurring after skin contact with a substance or a mixture. (h) Section 3.4.2.1.3.1 is replaced by the following: 3.4.2.1.3.1. Data from appropriate animal studies At present, recognised and validated animal models for the testing of respiratory hypersensitivity are not available. Under certain circumstances, data from animal studies may provide valuable information in a weight of evidence assessment. which may be indicative of the potential of a substance to cause sensitisation by inhalation in humans The mechanisms by which substances induce symptoms of asthma are not yet fully known. For preventative measures, these substances are considered respiratory sensitisers. However, if on the basis of the evidence, it can be demonstrated that these substances induce symptoms of asthma by irritation only in people with bronchial hyper-reactivity, they shall not be considered as respiratory sensitisers.
may include: (a) measurements of Immunoglobulin E (IgE) and other specific immunological parameters, for example in mice; (b) specific pulmonary responses in guinea pigs. (i) In section 3.4.3.3.2, Table 3.4.6, Note 1 is replaced by the following: Note 1: This concentration limit for elicitation is used for the application of the special labelling requirements of section 2.8 of Annex II to protect already sensitised individuals. A SDS is required for the mixture containing a component at or above this concentration. For sensitising substances with a specific concentration limit, the concentration limit for elicitation shall be set at a tenth of the specific concentration limit. (j) Section 3.5.1.1 is replaced by the following: 3.5.1.1. Germ cell mutagenicity means heritable gene mutations, including heritable structural and numerical chromosome aberrations in germ cells occurring after exposure to a substance or mixture. (k) Section 3.5.1.1 is renumbered as follows: 3.5.1.2. A mutation means a permanent change in the amount or structure of the genetic material in a cell. The term mutation applies both to heritable genetic changes that may be manifested at the phenotypic level and to the underlying DNA modifications when known (including specific base pair changes and chromosomal translocations). The term mutagenic and mutagen will be used for agents giving rise to an increased occurrence of mutations in populations of cells and/or organisms. (l) Section 3.5.1.2 is renumbered as follows: 3.5.1.3. The more general terms genotoxic and genotoxicity apply to agents or processes which alter the structure, information content, or segregation of DNA, including those which cause DNA damage by interfering with normal replication processes, or which in a non- physiological manner (temporarily) alter its replication. Genotoxicity test results are usually taken as indicators for mutagenic effects. (m) Section 3.5.2.3.5 is replaced by the following: 3.5.2.3.5. In vivo somatic cell mutagenicity tests, such as: mammalian bone marrow chromosome aberration test; mammalian erythrocyte micronucleus test (n) Section 3.6.1.1 is replaced by the following: 3.6.1.1. Carcinogenicity means the induction of cancer or an increase in the incidence of cancer occurring after exposure to a substance or mixture. Substances and mixtures which have induced benign and malignant tumours in well performed experimental studies on animals are considered also to be presumed or suspected human carcinogens unless there is strong evidence that the mechanism of tumour formation is not relevant for humans. Classification of a substance or mixture as posing a carcinogenic hazard is based on its intrinsic properties and does not provide information on the level of the human cancer risk which the use of the substance or mixture may represent. (o) Section 3.7.1.1 is replaced by the following: 3.7.1.1. Reproductive toxicity means adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring, occurring after exposure to a substance or mixture. The definitions presented below are adapted from those agreed as working definitions in IPCS/EHC Document No 225, Principles for Evaluating Health Risks to Reproduction Associated with Exposure to Chemicals. For classification purposes, the known induction of genetically based inheritable effects in the offspring is addressed in Germ Cell Mutagenicity (Section 3.5), since in the present classification system it is considered more appropriate to address such effects under the separate hazard class of germ cell mutagenicity.
In this classification system, reproductive toxicity is subdivided into two main headings: (a) adverse effects on sexual function and fertility; (b) adverse effects on development of the offspring. Some reproductive toxic effects cannot be clearly assigned to either impairment of sexual function and fertility or to developmental toxicity. Nonetheless, substances and mixtures with these effects shall be classified as reproductive toxicants with a general hazard statement. (p) Section 3.7.2.5.1 is replaced by the following: 3.7.2.5.1. A number of internationally accepted test methods are available; these include methods for developmental toxicity testing (e.g. OECD Test Guideline 414) and methods for one or two-generation toxicity testing (e.g. OECD Test Guidelines 415, 416, 443). (q) Section 3.8.1.1 is replaced by the following: 3.8.1.1. Specific target organ toxicity – single exposure means specific, non-lethal toxic effects on target organs occurring after a single exposure to a substance or mixture. All significant health effects that can impair function, both reversible and irreversible, immediate and/or delayed and not specifically addressed in sections 3.1 to 3.7 and 3.10 are included (see also section 3.8.1.6). (r) Section 3.8.3.4.1 is replaced by the following: 3.8.3.4.1. Where there is no reliable evidence or test data for the specific mixture itself, and the bridging principles cannot be used to enable classification, then classification of the mixture is based on the classification of the ingredient substances. In this case, the mixture shall be classified as a specific target organ toxicant (specific organ specified), following single exposure, when at least one ingredient has been classified as a Category 1 or Category 2 specific target organ toxicant (single exposure) and is present at or above the appropriate generic concentration limit as mentioned in Table 3.8.3 for Category 1 and 2 respectively. (s) In section 3.8.3.4, section 3.8.3.4.6 is added: 3.8.3.4.6. In cases where the additivity approach is used for Category 3 ingredients, the relevant ingredients of a mixture are those which are present in concentrations ≥ 1 % (w/w for solids, liquids, dusts, mists, and vapours and v/v for gases), unless there is a reason to suspect that an ingredient present at a concentration < 1 % is still relevant when classifying the mixture for respiratory tract irritation or narcotic effects. (t) Section 3.9.1.1 is replaced by the following: 3.9.1.1. Specific target organ toxicity-repeated exposure means specific toxic effects on target organs occurring after repeated exposure to a substances or mixture. All significant health effects that can impair function, reversible and irreversible, immediate and/or delayed are included. However, other specific toxic effects that are specifically addressed in sections 3.1 to 3.8 and 3.10 are not included here. (u) Section 3.9.3.4.1 is replaced by the following: 3.9.3.4.1. Where there is no reliable evidence or test data for the specific mixture itself, and the bridging principles cannot be used to enable classification, then classification of the mixture is based on the classification of the ingredient substances. In this case, the mixture shall be classified as a specific target organ toxicant (specific organ specified), following repeated exposure when at least one ingredient has been classified as a Category 1 or Category 2 specific target organ toxicant (repeated exposure) and is present at or above the appropriate generic concentration limit as laid out in Table 3.9.4 for Category 1 and 2 respectively.
(v) Section 3.10.1.3 is replaced by the following: 3.10.1.3. Aspiration hazard means severe acute effects such as chemical pneumonia, pulmonary injury or death occurring after aspiration of a substance or mixture. (w) In section 3.10.3.3 a new section is added: 3.10.3.3.1.1. The relevant ingredients of a mixture are those which are present in concentrations ≥ 1 %. (x) Section 3.10.3.3.1.1 is renumbered and replaced by the following: 3.10.3.3.1.2. A mixture is classified as Category 1 when the sum of the concentrations of Category 1 ingredients is ≥ 10 % and the mixture has a kinematic viscosity ≤ 20,5 mm2/s, measured at 40 °C. (y) Section 3.10.3.3.1.2 is renumbered and replaced by the following: 3.10.3.3.1.3. In the case of a mixture which separates into two or more distinct layers, the entire mixture is classified as Category 1 if in any distinct layer the sum of the concentrations of Category 1 ingredients is ≥ 10 %, and it has a kinematic viscosity ≤ 20,5 mm2/s, measured at 40 °C. 4. Part 4 is amended as follows: Section 4.1.3.5.5.3.1 is replaced by the following: 4.1.3.5.5.3.1. First, all components classified as Acute 1 are considered. If the sum of the concentrations (in %) of these components multiplied by their corresponding M-factors is ≥ 25 % the whole mixture is classified as Acute 1.
Annex
ANNEX II Annex II to Regulation (EC) No 1272/2008 is amended as follows:
- Part I is amended as follows: a) the following entry is deleted: 1.1.1. EUH001 — Explosive when dry For explosive substances and mixtures as referred to in section 2.1 of Annex I, placed on the market wetted with water or alcohols or diluted with other substances to suppress their explosive properties. b) Section 1.1.3 is renumbered as follows: 1.1.1 (c) Section 1.1.4 is renumbered as follows: 1.1.2 (d) Section 1.1.5 is renumbered as follows: 1.1.3 (e) Section 1.1.6 is renumbered as follows: 1.1.4
- Part II is amended as follows: In section 2.10 the third indent is replaced by the following: — ≥ one tenth of the specific concentration limit for a substance classified as skin sensitiser or respiratory sensitiser with a specific concentration limit, or
Annex
ANNEX III Annex III to Regulation (EC) No 1272/2008 is amended as follows:
- Part 1 is amended as follows: (a) The following Hazard Statements are added to Table 1.1: H206Language2.17 — Desensitised explosives, Hazard Category 1BGОпасност от пожар или разпръскване; повишен риск от експлозия при понижено съдържание на десенсибилизиращ агент.ESPeligro de incendio, onda expansiva o proyección; mayor riesgo de explosión si se reduce el agente insensibilizante.CSNebezpečí požáru, tlakové vlny nebo zasažení částicemi; zvýšené nebezpečí výbuchu, sníží-li se objem znecitlivujícího prostředku.DAFare for brand, eksplosion eller udslyngning af fragmenter; øget risiko for eksplosion, hvis det desensibiliserende middel reduceres.DEGefahr durch Feuer, Druckstoß oder Sprengstücke; erhöhte Explosionsgefahr wenn das Desensibilisierungsmittel reduziert wird.ETSüttimis-, plahvatus- või laialipaiskumisoht, desensibilisaatori vähenemise korral suurenenud plahvatusoht.ELΚίνδυνος πυρκαγιάς, ανατίναξης ή εκτόξευσης· αυξημένος κίνδυνος έκρηξης εάν μειωθεί ο παράγοντας απευαισθητοποίησης.ENFire, blast or projection hazard; increased risk of explosion if desensitising agent is reduced.FRDanger d'incendie, d'effet de souffle ou de projection; risque accru d'explosion si la quantité d'agent désensibilisateur est réduite.GAGuais dóiteáin, phléasctha nó teilgin; baol méadaithe pléasctha má laghdaítear an dí-íogróir.HROpasnost od vatre, udarnog vala ili rasprskavanja; povećan rizik od eksplozije ako je smanjen udio desenzitirajućeg agensa.ITPericolo d'incendio, di spostamento d'aria o di proiezione; maggior rischio di esplosione se l'agente desensibilizzante è ridotto.LVUgunsbīstamība, triecienviļņbīstamība vai izmetbīstamība; ja desensibilizācijas līdzekļa daudzums samazinājies, palielinās eksplozijas risks.LTGaisro, sprogimo arba išsvaidymo pavojus; sumažėjus desensibilizacijos veiksnio poveikiui kyla didesnė sprogimo rizika.HUTűz, robbanás vagy kivetés veszélye; fokozott robbanásveszély a deszenzibilizáló szer csökkenésével.MTPeriklu ta' nar, blast jew projjezzjoni; riskju ikbar ta' splużjoni jekk l-aġent disensitizzanti jitnaqqas.NLGevaar voor brand, luchtdrukwerking of scherfwerking; toegenomen ontploffingsgevaar als de ongevoeligheidsagens wordt verminderd.PLZagrożenie pożarem, wybuchem lub rozrzutem; zwiększone ryzyko wybuchu jeśli zawartość środka odczulającego została zmniejszona.
PTPerigo de incêndio, sopro ou projeções; risco acrescido de explosão se houver redução do agente dessensibilizante.ROPericol de incendiu, detonare sau proiectare; risc sporit de explozie dacă se reduce agentul de desensibilizare.SKNebezpečenstvo požiaru, výbuchu alebo rozletenia úlomkov; zvýšené riziko výbuchu, ak sa zníži obsah desenzibilizačného činidla.SLNevarnost za nastanek požara, udarnega vala ali drobcev; povečana nevarnost eksplozije, če se zmanjša vsebnost desenzibilizatorja.FIPalo-, räjähdys- tai sirpalevaara; suurentunut, jos flegmatointitekijää vähennetään.SVFara för brand, tryckvåg eller splitter och kaststycken, ökad explosionsrisk om det okänsliggörande ämnet minskas. H207Language2.17- Desensitised explosives, Hazard Category 2, 3BGОпасност от пожар или разпръскване; повишен риск от експлозия при понижено съдържание на десенсибилизиращ агент.ESPeligro de incendio o proyección; mayor riesgo de explosión si se reduce el agente insensibilizante.CSNebezpečí požáru nebo zasažení částicemi; zvýšené nebezpečí výbuchu, sníží-li se objem znecitlivujícího prostředku.DAFare for brand eller udslyngning af fragmenter; øget risiko for eksplosion, hvis det desensibiliserende middel reduceres.DEGefahr durch Feuer oder Sprengstücke; erhöhte Explosionsgefahr wenn das Desensibilisierungsmittel reduziert wird.ETSüttimis- või laialipaiskumisoht, desensibilisaatori vähenemise korral suurenenud plahvatusoht.ELΚίνδυνος πυρκαγιάς ή εκτόξευσης· αυξημένος κίνδυνος έκρηξης εάν μειωθεί ο παράγοντας απευαισθητοποίησης.ENFire or projection hazard; increased risk of explosion if desensitising agent is reduced.FRDanger d'incendie ou de projection; risque accru d'explosion si la quantité d'agent désensibilisateur est réduite.GAGuais dóiteáin nó teilgin; baol méadaithe pléasctha má laghdaítear an dí-íogróir.HROpasnost od vatre ili rasprskavanja; povećan rizik od eksplozije ako je smanjen udio desenzitirajućeg agensa.ITPericolo d'incendio o di proiezione; maggior rischio di esplosione se l'agente desensibilizzante è ridotto.LVUgunsbīstamība vai izmetbīstamība; ja desensibilizācijas līdzekļa daudzums samazinājies, palielinās eksplozijas risks.LTGaisro arba išsvaidymo pavojus; sumažėjus desensibilizacijos veiksnio poveikiui kyla didesnė sprogimo rizika. HUTűz vagy kivetés veszélye; fokozott robbanásveszély a deszenzibilizáló szer csökkenésével.MTPeriklu ta' nar jew projezzjoni; riskju ikbar ta' splużjoni jekk l-aġent disensitizzanti jitnaqqas.NLGevaar voor brand of scherfwerking; toegenomen ontploffingsgevaar als de ongevoeligheidsagens wordt verminderd.PLZagrożenie pożarem lub rozrzutem; zwiększone ryzyko wybuchu jeśli zawartość środka odczulającego została zmniejszona.PTPerigo de incêndio ou projeções; risco acrescido de explosão se houver redução do agente dessensibilizante.ROPericol de incendiu sau proiectare; risc sporit de explozie dacă se reduce agentul de desensibilizare.SKNebezpečenstvo požiaru alebo rozletenia úlomkov; zvýšené riziko výbuchu, ak sa zníži obsah desenzibilizačného činidla.SLNevarnost za nastanek požara ali drobcev; povečana nevarnost eksplozije, če se zmanjša vsebnost desenzibilizatorja.FIPalo- tai sirpalevaara; suurentunut, jos flegmatointitekijää vähennetään.SVFara för brand eller splitter och kaststycken. ökad explosionsrisk om det okänsliggörande ämnet minskas.
H208Language2.17 — Desensitised explosives, Hazard Category 4BGОпасност от пожар; повишен риск от експлозия при понижено съдържание на десенсибилизиращ агент.ESPeligro de incendio; mayor riesgo de explosión si se reduce el agente insensibilizante.CSNebezpečí požáru; zvýšené nebezpečí výbuchu, sníží-li se objem znecitlivujícího prostředku.DABrandfare; øget risiko for eksplosion, hvis det desensibiliserende middel reduceres.DEGefahr durch Feuer; erhöhte Explosionsgefahr wenn das Desensibilisierungsmittel reduziert wird.ETSüttimisoht; desensibilisaatori vähenemise korral suurenenud plahvatusoht.ELΚίνδυνος πυρκαγιάς· αυξημένος κίνδυνος έκρηξης εάν μειωθεί ο παράγοντας απευαισθητοποίησης.ENFire hazard; increased risk of explosion if desensitising agent is reduced.FRDanger d'incendie; risque accru d'explosion si la quantité d'agent désensibilisateur est réduite.GAGuais dóiteáin; baol méadaithe pléasctha má laghdaítear an dí-íogróir.HROpasnost od vatre; povećan rizik od eksplozije ako je smanjen udio desenzitirajućeg agensa.ITPericolo d'incendio; maggior rischio di esplosione se l'agente desensibilizzante è ridotto. LVUgunsbīstamība; ja desensibilizācijas līdzekļa daudzums samazinājies, palielinās eksplozijas risks.LTGaisro pavojus; sumažėjus desensibilizacijos veiksnio poveikiui kyla didesnė sprogimo rizika.HUTűz veszélye; fokozott robbanásveszély a deszenzibilizáló szer csökkenésével.MTPeriklu ta' nar; riskju ikbar ta' splużjoni jekk l-aġent disensitizzanti jitnaqqas.NLGevaar voor brand; toegenomen ontploffingsgevaar als de ongevoeligheidsagens wordt verminderd.PLZagrożenie pożarem; zwiększone ryzyko wybuchu jeśli zawartość środka odczulającego została zmniejszona.PTPerigo de incêndio; risco acrescido de explosão se houver redução do agente dessensibilizante.ROPericol de incendiu; risc sporit de explozie dacă se reduce agentul de desensibilizare.SKNebezpečenstvo požiaru; zvýšené riziko výbuchu, ak sa zníži obsah desenzibilizačného činidla.SLNevarnost za nastanek požara; povečana nevarnost eksplozije, če se zmanjša vsebnost desenzibilizatorja.FIPalovaara; suurentunut, jos flegmatointitekijää vähennetään.SVFara för brand, ökad explosionsrisk om det okänsliggörande ämnet minskas. H232Language2.2 — Flammable gases, Hazard Category 1A, pyrophoric gasBGМоже да се запали спонтанно при контакт с въздух.ESPuede inflamarse espontáneamente en contacto con el aire.CSPři styku se vzduchem se může samovolně vznítit.DAKan selvantænde ved kontakt med luft.DEKann sich bei Kontakt mit Luft spontan entzünden.ETKokkupuutel õhuga võib süttida iseenesest.ELΕνδέχεται να αυτοαναφλεγεί εάν εκτεθεί στον αέρα.ENMay ignite spontaneously if exposed to air.FRPeut s'enflammer spontanément au contact de l'air.GAD'fhéadfadh an ní uathadhaint i gcás nochtadh don aer.HRMože se spontano zapaliti u dodiru sa zrakom.ITSpontaneamente infiammabile all'aria.LVSaskarē ar gaisu var spontāni aizdegties.LTOre gali užsidegti savaime. HULevegővel érintkezve öngyulladásra hajlamos.MTJista' jieħu n-nar spontanjament jekk ikun espost għall-arja.NLKan spontaan ontbranden bij blootstelling aan lucht.PLMoże ulegać samozapaleniu w przypadku wystawienia na działanie powietrza.PTPode inflamar-se espontaneamente em contacto com o ar.ROSe poate aprinde spontan dacă intră în contact cu aerul.SKPri kontakte so vzduchom sa môže spontánne vznietit.SLV stiku z zrakom lahko pride do samodejnega vžiga.FIVoi syttyä itsestään palamaan joutuessaan kosketuksiin ilman kanssa.SVKan spontanantända vid kontakt med luft.
(b) Table 1.1 is amended as follows: (i) The top row of the entry concerning H220 is replaced by the following: H220Language2.2 – Flammable gases, Hazard Category 1A (ii) The top row of the entry concerning H221 is replaced by the following: H221Language2.2 – Flammable gases, Hazard Category 1B, 2 (iii) The top row of the entry concerning H230 is replaced by the following: H230Language2.2 — Flammable gases, Hazard Category 1A, chemically unstable gas A (iv) The top row of the entry concerning H231 is replaced by the following: H231Language2.2 — Flammable gases, Hazard Category 1A, chemically unstable gas B (c) The 10th row of the entry concerning H314 is replaced by the following: FRProvoque de graves brûlures de la peau et de graves lésions des yeux. 2. Part 2 is amended as follows: (a) In Table 2.1 the entry for EUH 001 is deleted.
Annex
ANNEX IV Annex IV to Regulation (EC) No 1272/2008 is amended as follows: (1) The first introductory paragraph of Annex IV is replaced by the following: This Annex sets out a matrix listing the recommended precautionary statements for each hazard class and hazard category by type of precautionary statement. The matrix guides the selection of appropriate precautionary statements, and includes elements for all categories of precautionary action. All specific elements relating to particular hazard classes shall be used. In addition, general precautionary statements not linked to a certain hazard class or category shall also be used where relevant. To provide flexibility in the application of precautionary phrases, combinations or consolidations of precautionary statements are encouraged to save label space and improve readability. The matrix and the Tables in Part 1 of this Annex include a number of combined precautionary statements. However, these are only examples and suppliers may further combine and consolidate phrases where this contributes to clarity and comprehensibility of label information in accordance with Articles 22 and 28(3). Notwithstanding Article 22 the precautionary statements that appear on labels or in safety data sheets may incorporate minor textual variations from those set out in this Annex where these variations assist in communicating safety information and the safety advice is not diluted or compromised. These may include spelling variations, synonyms or other equivalent terms appropriate to the region where the product is supplied and used. (2) Table 6.1 is amended as follows: The entry concerning code P103 is replaced by the following: P103Read carefully and follow all instructions.as appropriateConsumer products – omit where P202 is used (3) Table 6.2 is amended as follows: (a) The entries concerning codes P201 and P202 are replaced by the following: P201Obtain special instructions before use.Explosives (section 2.1)Unstable explosiveGerm cell mutagenicity (section 3.5)1A,1B, 2Consumer products – omit where P202 is usedCarcinogenicity (section 3.6)1A,1B, 2Reproductive toxicity (section 3.7)1A,1B, 2Reproductive toxicity — effects on or via lactation (section 3.7)Additional categoryP202Do not handle until all safety precautions have been read and understood.Flammable gases (section 2.2)A, B (chemically unstable gases)Germ cell mutagenicity (section 3.5)1A,1B, 2Carcinogenicity (section 3.6)1A,1B, 2Reproductive toxicity (section 3.7)1A,1B, 2Reproductive toxicity, effects on or via lactation (section 3.7)Additional category
(b) The entry concerning code P210 is replaced by the following: P210Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.Explosives (section 2.1)Divisions 1.1, 1.2, 1.3, 1.4, 1.5Flammable gases (section 2.2)1A, 1B, 2Aerosols (section 2.3)1, 2, 3Flammable liquids (section 2.6)1, 2, 3Flammable solids (section 2.7)1, 2Self-reactive substances and mixtures (section 2.8)Types A, B, C, D, E, FPyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1Oxidising liquids (section 2.13)1, 2, 3Oxidising solids (section 2.14)1, 2, 3Organic peroxides (section 2.15)Types A, B, C, D, E, FDesensitised explosives (section 2.17)1, 2, 3, 4 (c) The entry concerning code P212 is inserted: P212Avoid heating under confinement or reduction of the desensitising agent.Desensitised explosives (section 2.17)1, 2, 3, 4 (d) The entry concerning code P222 is replaced by the following: P222Do not allow contact with air.Flammable gases (section 2.2)Pyrophoric gas if emphasis of the hazard statement is deemed necessary. Pyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1 (e) The entry concerning code P230 is replaced by the following: P230Keep wetted with …Explosives (section 2.1)Divisions 1.1, 1.2, 1.3, 1.5 Manufacturer/supplier to specify appropriate material for substances and mixtures which are wetted, diluted, dissolved or suspended with a phlegmatiser in order to suppress their explosive properties Desensitised explosives (section 2.17)1, 2, 3, 4Manufacturer/supplier to specify appropriate material (f) The entry concerning code P233 is replaced by the following: P233Keep container tightly closed.Flammable liquids (section 2.6)1, 2, 3 if the liquid is volatile and may generate an explosive atmosphere Pyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1Desensitised explosives (section 2.17)1, 2, 3, 4Acute toxicity – inhalation (section 3.1)1, 2, 3 if the chemical is volatile and may generate a hazardous atmosphere Specific target organ toxicity – single exposure; respiratory tract irritation (section 3.8)3Specific target organ toxicity – single exposure; narcotic effects (section 3.8)3 (g) The entry concerning code P280 is replaced by the following: P280Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/…Explosives (section 2.1)Unstable explosive and divisions 1.1, 1.2, 1.3, 1.4, 1.5Manufacturer/supplier to specify the appropriate type of personal protective equipment.Flammable gases (section 2.2)Pyrophoric gasFlammable liquids (section 2.6)1, 2, 3Flammable solids (section 2.7)1, 2Self-reactive substances and mixtures (section 2.8)Types A, B, C, D, E, FPyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1Self-heating substances and mixtures (section 2.11)1, 2Substances and mixtures which, in contact with water, emit flammable gases (section 2.12)1, 2, 3Oxidizing liquids (section 2.13)1, 2, 3Oxidizing solids (section 2.14)1, 2, 3 Organic peroxides (section 2.15)Types A, B, C, D, E, FDesensitised explosives (section 2.17)1, 2, 3, 4Acute toxicity – dermal (section 3.1)1, 2, 3, 4
Specify protective gloves/clothing. Manufacturer/supplier may further specify type of equipment where appropriate. Skin corrosion (section 3.2)1A, 1B, 1C Specify protective gloves/clothing and eye/face protection. Manufacturer/supplier may further specify type of equipment where appropriate. Skin irritation (section 3.2)2 Specify protective gloves. Manufacturer/supplier may further specify type of equipment where appropriate. Skin sensitisation (section 3.4)1, 1A, 1BSerious eye damage (section 3.3)1 Specify eye/face protection. Manufacturer/supplier may further specify type of equipment where appropriate. Eye irritation (section 3.3)2Germ cell mutagenicity (section 3.5)1A, 1B, 2Manufacturer/supplier to specify the appropriate type of personal protective equipment.Carcinogenicity (section 3.6)1A, 1B, 2Reproductive toxicity (section 3.7)1A, 1B, 2 (4) Table 6.3 is amended as follows: (a) The entries concerning codes P301 and P302 are replaced by the following: P301IF SWALLOWED:Acute toxicity – oral (section 3.1)1, 2, 3, 4Skin corrosion (section 3.2)1, 1A, 1B, 1CAspiration Hazard (section 3.10)1P302IF ON SKIN:Pyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1Substances and mixtures which, in contact with water, emit flammable gases (section 2.12)1, 2 Acute toxicity – dermal (section 3.1)1, 2, 3, 4Skin irritation (section 3.2)2Skin sensitisation (section 3.4)1, 1A, 1B (b) The entry concerning code P332 is replaced by the following: P332If skin irritation occurs:Skin irritation (section 3.2)2may be omitted if P333 is given on the label. (c) The entry concerning codes P370 and P371 are replaced by the following: P370In case of fire:Explosives (section 2.1)Unstable explosives and divisions 1.1, 1.2, 1.3, 1.4, 1.5Oxidising gases (section 2.4)1Flammable liquids (section 2.6)1, 2, 3Flammable solids (section 2.7)1, 2Self-reactive substances and mixtures (section 2.8)Types A, B, C, D, E, FPyrophoric liquids (section 2.9)1Pyrophoric solids (section 2.10)1Substances and mixtures which, in contact with water, emit flammable gases (section 2.12)1, 2, 3Oxidising liquids (section 2.13)1, 2, 3Oxidising solids (section 2.14)1, 2, 3Organic Peroxides (section 2.15)Types A, B, C, D, E, FDesensitised explosives (section 2.17)1, 2, 3P371In case of major fire and large quantities:Oxidising liquids (section 2.13)1Oxidising solids (section 2.14)1Desensitised explosives (section 2.17)4 (d) The entry concerning code P375 is replaced by the following: P375Fight fire remotely due to the risk of explosion.Explosives (section 2.1)Division 1.4 for explosives of division 1.4 (compatibility group S) in transport packaging. Self-reactive substances and mixtures (section 2.8)Type BOxidising liquids (section 2.13)1Oxidising solids (section 2.14)1Organic peroxides (section 2.15)Type BDesensitised explosives (section 2.17)1, 2, 3, 4 (e) The entry concerning code P377 is replaced by the following: P377Leaking gas fire: Do not extinguish, unless leak can be stopped safely.Flammable gases (section 2.2)1A, 1B, 2
(f) The entry concerning code P380 is replaced by the following: P380Evacuate area.Explosives (section 2.1)Unstable explosives and Divisions 1.1, 1.2, 1.3, 1.4, 1.5Self-reactive substances and mixtures (section 2.8)Types A, BOxidising liquids (section 2.13)1Oxidising solids (section 2.14)1Organic peroxides (section 2.15)Types A, BDesensitised explosives (section 2.17)1, 2, 3, 4 (g) The entry concerning code P381 is replaced by the following: P381In case of leakage, eliminate all ignition sourcesFlammable gases (section 2.2)1A, 1B, 2 (h) The entry concerning code P301 + P312 is replaced by the following: P301 + P312IF SWALLOWED: Call a POISON CENTER/doctor/… if you feel unwellAcute toxicity – oral (section 3.1)4… Manufacturer/supplier to specify the appropriate source of emergency medical advice (i) The entries concerning codes P370 + P380 + P375 and P371 + P380 + P375 are replaced by the following: P370 + P380 + P375In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion.Explosives (section 2.1)Division 1.4 for explosives of division 1.4 (compatibility group S) in transport packaging Desensitised explosives (section 2.17)1, 2, 3P371 + P380 + P375In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion.Oxidising liquids (section 2.13)1Oxidising solids (section 2.14)1Desensitised explosives (section 2.17)4 (5) Table 6.4 is amended as follows: (a) The entry concerning code P401 is replaced by the following: P401Store in accordance with …Explosives (section 2.1)Unstable explosives and Divisions 1.1, 1.2, 1.3, 1.4, 1.5… Manufacturer/supplier to specify local/regional/national/international regulations as applicable.Desensitised explosives (section 2.17)1, 2, 3, 4 (b) The entry concerning code P403 is replaced by the following: P403Store in a well-ventilated place.Flammable gases (section 2.2)1A, 1B, 2Oxidising gases (section 2.4)1Gases under pressure (section 2.5)Compressed gasLiquefied gasRefrigerated liquefied gasDissolved gasFlammable liquids (section 2.6)1, 2, 3 for flammable liquids Category 1 and other flammable liquids that are volatile and may generate an explosive atmosphere. Self-reactive substances and mixtures (section 2.8)Types A, B, C, D, E, F except for temperature controlled self-reactive substances and mixtures or organic peroxides because condensation and consequent freezing may take place. Organic peroxides (section 2.15)Acute toxicity – inhalation (section 3.1)1, 2, 3 if the substance or mixture is volatile and may generate a hazardous atmosphere. Specific target organ toxicity – single exposure; respiratory tract irritation (section 3.8)3Specific target organ toxicity – single exposure; narcotic effects (section 3.8)3 (6) Table 6.5 is amended as follows: (a) The entry concerning code P501 is replaced by the following: P501Dispose of contents/container to …Flammable liquids (section 2.6)1, 2, 3 … in accordance with local/regional/national/international regulation (to be specified).
Manufacturer/supplier to specify whether disposal requirements apply to contents, container or both. Self-reactive substances and mixtures (section 2.8)Types A, B, C, D, E, FSubstances and mixtures which, in contact with water, emit flammable gases (section 2.12)1, 2, 3Oxidising liquids (section 2.13)1, 2, 3Oxidising solids (section 2.14)1, 2, 3Organic peroxides (section 2.15)Types A, B, C, D, E, FDesensitised explosives (section 2.17)1, 2, 3, 4Acute toxicity – oral (section 3.1)1, 2, 3, 4Acute toxicity – dermal (section 3.1)1, 2, 3, 4Acute toxicity – inhalation (section 3.1)1, 2, 3Skin corrosion (section 3.2)1, 1A, 1B, 1CRespiratory sensitisation (section 3.4)1, 1A, 1BSkin sensitisation (section 3.4)1, 1A, 1B Germ cell mutagenicity (section 3.5)1A, 1B, 2Carcinogenicity (section 3.6)1A, 1B, 2Reproductive toxicity (section 3.7)1A, 1B, 2Specific target organ toxicity – single exposure (section 3.8)1, 2Specific target organ toxicity – single exposure; respiratory tract irritation (section 3.8)3Specific target organ toxicity – single exposure; narcotic effects (section 3.8)3Specific target organ toxicity – repeated exposure (section 3.9)1, 2Aspiration hazard (section 3.10)1Hazardous to the aquatic environment – acute aquatic hazard (section 4.1)1Hazardous to the aquatic environment – chronic aquatic hazard (section 4.1)1, 2, 3, 4 (b) The following new entry is inserted after code P502: P503Refer to manufacturer/ supplier/… for information on disposal/recovery/ recyclingExplosives (section 2.1)Unstable explosives and Divisions 1.1, 1.2, 1.3, 1.4, 1.5… Manufacturer/supplier to specify appropriate source of information in accordance with local/regional/national/international regulations as applicable. (7) Table 1.2 is amended as follows: (a) The following new entry is inserted: P212LanguageBGДа се избягва нагряване в затворено пространство или понижаване на съдържанието на десенсибилизиращия агент.ESEvitar el calentamiento en condiciones de aislamiento o la reducción del agente insensibilizante.CSZamezte zahřívání v uzavřeném obalu nebo snížení objemu znecitlivujícího prostředku.DAUndgå opvarmning under indeslutning eller reduktion af det desensibiliserende middel." DEErhitzen unter Einschluss und Reduzierung des Desensibilisierungsmittels vermeiden.ETVältida suletuna kuumutamist ja desensibilisaatori vähenemist.ELΝα αποφεύγεται η θέρμανση σε περιορισμένο χώρο και η μείωση του παράγοντα απευαισθητοποίησης.ENAvoid heating under confinement or reduction of the desensitising agent.FRÉviter d'échauffer en milieu confiné ou en cas de diminution de la quantité d'agent désensibilisateur.GASeachain an téamh i limistéar iata nó i gcás laghdú ar an dí-íogróir.HRIzbjegavati zagrijavanje u zatvorenom prostoru ili smanjenje udjela desenzitirajućeg agensa.ITEvitare di riscaldare sotto confinamento o di ridurre l'agente desensibilizzante.LVNepieļaut karsēšanu slēgtā vidē vai desensibilizējošā aģenta daudzuma samazināšanos.”LTVengti kaitimo uždaroje talpykloje arba desensibilizacijos veiksnio poveikio sumažėjimo.HUKerülje a hevítést zárt térben vagy a deszenzibilizáló szer mennyiségének csökkenése esetén.MTEvita t-tisħin fil-magħluq jew it-tnaqqis tal-aġenti disensitizzanti.NLVermijd verwarming onder opsluiting of vermindering van de ongevoeligheidsagens.PLUnikać ogrzewania pod zamknięciem lub w sytuacji zmniejszonej zawartości środka odczulającego.”PTEvitar o aquecimento em ambiente fechado ou a redução do agente dessensibilizado.»ROA se evita încălzirea în mediu confinat sau în caz de scădere a agentului de desensibilizareSKZabráňte zahrievaniu v ohraničenom priestore alebo zníženiu obsahu desenzibilizačného činidla.SLIzogibati se segrevanju v zaprtem prostoru ali zmanjšanju vsebnosti desenzibilizatorja.“.FIVältettävä kuumentamista suljetussa astiassa tai flegmatointiaineen vähentämistä.SVUndvik uppvärmning i sluten behållare eller reducering av det okänsliggörande ämnet.
Annex
ANNEX V Part 1, section 1.2 of Annex V to Regulation (EC) No 1272/2008 is amended as follows: (a) In column 2, the sentence Flammable gases, hazard category 1 is replaced by Flammable gases, hazard categories 1A, 1B. (b) In column 2, the sentence Section 2.17 Desensitised explosives, hazard categories 1, 2, 3, 4 is added after the last entry.
Annex
ANNEX VI Part 1 of Annex VI to Regulation (EC) No 1272/2008 is amended as follows: (a) In Table 1.1 the row concerning Flammable gases is replaced by the following: Flammable gases Flam. Gas 1A Flam. Gas 1B Flam. Gas 2 Pyr. Gas Chem. Unst. Gas A Chem. Unst. Gas B (b) In Table 1.1 the following row is added after the row Substance or mixture corrosive to metals: Desensitised explosives Desen. Expl. 1 Desen. Expl. 2 Desen. Expl. 3 Desen. Expl. 4
Metadata
- Type
- Forordning
- År
- 2019
- Ikrafttrædelsesdato
- 1. januar 1970